Placement and lifting
Chillers and dry coolers are lifted onto plinths or roofs with crane or forklift, positioned with service clearance and levelled.
Sahajanand Services is an authorized Frigosystem partner. We install, pipe up and commission process chillers that cool plastics extrusion and converting lines.


Film and sheet lines depend on stable cooling. Chill rolls, air rings, extruder feed throats and hydraulic units all draw chilled water, and a chiller that swings in temperature shows up as gauge variation, poor clarity and unstable film. The chiller is a process machine, not a utility to be added at the end.
Frigosystem India Private Limited, based in Kanchipuram, lists water chillers, air chillers, temperature controllers, dry coolers and pumping systems. Sahajanand Services is an authorized Frigosystem sales and service partner and handles the site work: placing the unit, piping, electrical connection and commissioning. Chilled water systems are sized to the heat load of the line, so we ask for the extruder output and the cooling points before a unit is selected.
Because we also erect the extrusion lines these chillers serve, we can coordinate the chilled water circuit with the line itself, so pipe routes, pump capacity and control signals are planned in one program and not fixed after the line is erected. That avoids rework when the chiller is installed late.
A chiller is only as good as the circuit around it. These are the parts of the job we cover.
Chillers and dry coolers are lifted onto plinths or roofs with crane or forklift, positioned with service clearance and levelled.
We connect supply and return lines to the process, fit isolation valves, strainers and vents, and flush the circuit before the unit is charged with water.
Power and control cables are terminated, phase sequence is checked, and the chiller is linked to the line's control panel where required.
Flow, pressure drop and setpoint are verified, and the chiller is run under real load from the extrusion line to confirm it holds temperature.
On a blown film line, the air ring and internal bubble cooling control how fast the melt freezes. On a cast film line, the chill roll surface temperature sets film clarity and flatness. In both cases a drift of a few degrees changes the product.
During commissioning we check that flow reaches each consumer, that air is vented from the loop, and that the chiller does not short-cycle at part load. Glycol or water treatment is set according to the plant's requirement.
We confirm placement, clearances, drain and power supply.
The unit is lifted into place and levelled.
Water lines and electrical cables are connected and tested.
The chiller is started, balanced and run with the line.
Yes. We are an authorized sales and service partner for Frigosystem in India.
Its site lists water chillers (including the RACA, HC, HCA, RPE and RHD series), air chillers, temperature controllers, adiabatic dry coolers and pumping systems.
Yes. We erect the line and the chiller in one program, so piping routes and electrical interfaces are planned together.
Yes. Contact us on +91 87803 54331 with the model and the fault, and we will arrange a visit.
Tell us what you're moving or installing. We reply within one business day with next steps and a clear, written scope.